Dissolved Acetylene Plant
MOS Techno Engineers know amoung the Manufacturer & Exporter of Dissolved Acetylene Gas Plant. Our team of expert engineers has built Acetylene Gas Plants that combined diverse features that are not generally found in other Acetylene Plants. These plants are built keeping in mind the international ASME standards. These acetylene generator plants operate a fully automated operation with dual hoppers tanks and all the operations are executed by pneumatically controlled valves supported by deeply precise sensors and complete with the temperature control panel.
Acetylene gas plants are constructed with the implementing of the latest cutting-edge technology. We deliver the Acetylene Generator plants in various categories ranging from 25m3/hour to 200m3/hour. Our Acetylene plants are also quite intended and are appraised competitively. The dissolved acetylene plant is built in compliance with international standards.
The acetylene gas produced is highly combustible and flammable, if combined with air. Consequently, various safety equipment and automatic systems are combined to prevent fire or any other threat. These fully automated sophisticated safety equipment secure the acetylene gas plant while the plant is in operation. The whole process is flawlessly synchronized to provide maximum performance and uniformity in the production process. In case of any interruption in the production process whether it is of power supply, water, instruments air, is indicated visually and also audibly during an alert alarm rings to inform the plant operator.
Specifications of Dissolved Acetylene Plant
Specifications | For 45cu.m/hr Acetylene Plant | For 100cu.m/hr Acetylene Plant | |
I | Capacity | 45 cu.metre/hr of Acetylene | 100 cu.metre/hr of Acetylene |
Cylinders filled per batch | 60 Cylinders | 120 Cylinders | |
Carbide Size | 4-50 mm | 4-50 mm | |
Hopper Capacity | 150 Kg | 300 Kg | |
Carbide required per batch | 1, 200 Kg approximately (depending on Carbide quality) | 2, 700 Kg approximately (depending on Carbide quality) | |
Water required | 10 ltrs. per kg of Calcium Carbide used | 10 ltrs. per kg of Calcium Carbide used | |
Power requirement | 18 KW | 30 KW | |
Start up time | 15 minutes | 15 minutes | |
II | I.S. Specifications conforms to: a) Acetylene Generator b) Flame Proof Motors | IS 8471 – 1977 IS 2148 (Group II-B)-1968 | IS 8471 – 1977 IS 2148 (Group II-B)-1968 |
III | Statutory requirement of distances as per Explosive Dept. | a) Acetylene Plant and Carbide godown should be: 9 metres form lime pits 15 metres from public road 15 metres from Electricity room 15 metres from any other building 90 metres from Oxygen Plant air intake point and 30 metres from Oxygen Plant Building. | a) Acetylene Plant and Carbide godown should be: 9 metres form lime pits 15 metres from public road 15 metres from Electricity room 15 metres from any other building 90 metres from Oxygen Plant air intake point and 30 metres from Oxygen Plant Building. |
b) Acetone godown of 2,500 litres capacity should be 6 metres from any other premises | b) Acetone godown of 2,500 litres capacity should be 6 metres from any other premises | ||
IV | Power Supply | 440 Volts/3 phase/50 hertz (if your supply is different from this please specify to enable us quote accordingly) | 440 Volts/3 phase/50 hertz (if your supply is different from this please specify to enable us quote accordingly) |